Preparing to Install and Configure Qualitia for Automation Testing

Qualitia is a scriptless test automation platform. Using Qualitia, you can implement automation for your Web, Desktop, and Mobile applications. 

Before you start installing Qualitia, make sure that the following requirements are fulfilled:

  1. Download Qualitia Automation Studio for Web and Mobile.
  2. /wiki/spaces/TEST1/pages/1718944196.
  3. Ensure that the machine where you plan to install Qualitia Server and Qualitia Client meets all minimum system requirements.
  4. Ensure that an appropriate UTC Time Zone is set for the server, anything other than UTC (Coordinated Universal Time).
  5. Ensure that you have access to different communication ports required from Qualitia Server and Client machines.

Important Notice

It is strongly recommended to keep the database server and Qualitia server in the same local network (LAN). Keeping them in different network environments will result in performance issues due to network latency.


System, Database, and Network Privileges

Depending on your organizational policies and structure, you may have to interact with following roles and departments:

  • Server / System Administrator
  • Database Administrator
  • Network Administrator

Server / System Administrator

In order to install and access Qualitia Automation Studio (Server and Client), you must have Local Administrator privileges on the respective machines.

Additionally, you must white list Qualitia.exe in the virus checking (also known as Anti-virus) software.

Database Administrator

Qualitia Automation Studio requires a relational database to store its test case related data. You can choose Microsoft SQL or My SQL relational servers to store the data based on your requirements. Qualitia users must have the following privileges to the databases:

DatabasesPermissions on Qualitia Databases
Microsoft SQLDBO Privileges
MySQLGrant All Privileges

Network Administrator

Qualitia needs access to a few network ports to communicate between components like Version Control, Data Store Servers and so forth. Depending on your organizational policies and structure, you may have to place requests to open certain ports on the machine where Qualitia Server is installed. 

Following is the list of all the communication ports Qualitia needs access to:

1947
  • Qualitia Licensing Service (on Client and Server machines)
8889
  • Qualitia Server
8887
  • Qualitia Web Service
1433
  • MS SQL Server (Data Store Server)
3306
  • MySQL Server (Data Store Server)
80
  • Apache Subversion (Versioning and Revision Control System)
4001
  • Mobile Object Spy Server
21000 to 22000
  • Mobile Object Spy Agent (any port from the specified range)

All the port numbers mentioned above are the default communication ports used by these applications. In case you are changing the default ports, you must open or unblock corresponding ports.  