What’s New in this release?
These release notes provide information about the new features added to Qualitia Automation Studio. They also provide details about the enhancements done, bugs fixed, and known issues in this release.
We are happy to announce the release of Qualitia Automation Studio 8.2.0.
We are bringing you some exciting new features that will take user experience to a whole new level.
With every step, we strive to make automation development with Qualitia even easier, even faster, and even more reliable.
What’s New?
Brand new UI!
Isn’t it always a delight to use a product that has been made with care and attention, and with the user at the center of its existence?
We are excited to unveil our spanking new user interface!
Here are the highlights:
We have created a clean, modern look with upgraded icons, and menus that can be expanded and collapsed.
The new interface is clutter-free and more intuitive to navigate.
Keeping the user’s comfort in mind, we have clubbed together the General, Project and Execution Settings to provide a single-screen search experience.
We have made our test suite execution feature even more robust by giving it a UI boost.
Managing execution profiles while executing test suites is now simpler with easy visibility of the chosen settings.
You no longer need to remember (or have to dig deeper to figure out) which execution profile fulfills what purpose.
You can easily edit execution profiles right from the test suite screen.
Managing Tasks is now even better!
In Qualitia Automation Studio, maintaining each task as an independent reusable component helps saves significant amounts of time and efforts for our users.
We have now gone even further in making this feature super-powerful:
We have introduced the Import Tasks feature that enables you to reuse tasks across projects by importing them, thus boosting efficiency with minimal maintenance efforts.
For more information, refer to Importing Tasks from Another Project.The new UI even differentiates between tasks that are new, changed or already imported to enable more structured usage across projects.
Working with tasks has now become easier:
When any task is changed by someone, all test cases where it is present, get highlighted with a red underline.
Even better, when you open that test case, we also tell you exactly which task and which steps within that task have changed.
This helps you quickly analyze the impact of that change on your test cases and take appropriate actions to prevent any unnecessary test case execution failures.
This helps avoid significant investigative efforts spent in identifying the root problem, which is caused by unknown changes in tasks.
We now make it easy to differentiate between task steps and test case steps by highlighting them in white and grey colors respectively.
We are confident that this latest version of Qualitia Automation Studio will further enhance your experience and help you make your test automation projects highly successful.
We remain committed to a process of continuous improvement and look forward to receiving any feedback that you might have for us.
Enhancements
Features Improvements
The action execution logs now contain additional details to improve the troubleshooting of the test cases executed on desktop web and mobile web environments.
You can now enable the SmartLocator feature for the mobile web objects also.
The SmartLocator feature does not change the object properties, such as locator type and locator value, during test case execution. The objects are searched at the run-time and their properties are displayed in the suite execution report.
You can now enable or disable the Legacy option to view the Qualitia Reports and Dashboard in the old or new format.
QAS Components Installers
The overall QAS components installer package size has been reduced significantly, which helps you to download the QAS components installers quickly.
Pre-requisite Checks by QAS Installers
The QAS client installer now checks whether compatible versions of Java and .Net Framework are installed on your computer.
The Mobile ObjectSpy installer now checks whether compatible versions of Java, .Net Framework, and Android Debug Bridge are installed on your computer.
You can now repair the Qualitia services that are not working using the QAS Server desktop shortcut.
Qualitia now provides a list of database privileges for SQL Server and MySQL that are required to install or upgrade the Qualitia Server. Earlier, the database administrator-level privilege was required to install or upgrade the Qualitia Server.
Known Issues
General Issues
The sorting of test cases in the Scenarios tree is lost when using the Search Test Cases feature.
You cannot add or edit the properties of a custom action in a single click. You need to click the properties that you want to modify thrice.
The following issues are seen while using the Search feature in the Environment Variabe dialog box:
You cannot add a variable or edit a key.
If you update any environment variable, change the text in the Search box, and then update another variable, then only the last edited input variable is saved.
In the Import screen, if you scroll down the tasks in the New and Conflicted sections, the New and Conflicted labels are not freezed.
After you import a task into a current project and update the corresponding task in the import project to add or delete a step, and then revert the changes, then in the Import screen, the import project task is displayed under the Conflicted Tasks section. Selecting the conflicted task does not show any changes.
After skipping a highlighted step and saving the test case, the red underline of that step disappears. However, reverting the changes by unskipping the same step and saving the test case does not fix the problems. If you want the red underline to appear, switch to other tabs, such as tasks or objects within the Development module, and then return to the test case screen.
If a test case is highlighted with steps, then the test case name that is displayed above the first step of the test case is not highlighted. If you switch to another tab, such as tasks or objects within the Development module, and then return to the test case screen, the test case name in the same is now highlighted.
Desktop Projects
Updating objects in a TSR file that is used in two or more projects does not reflect the changes properly in all the projects. When you update an object in the TSR file and synchronize the changes in the first project, the changes to the updated object are displayed properly. However, when you synchronize the TSR file in the second project, the original object that was updated is displayed as deleted, while the updated object is displayed as a new object.
Perfecto
The mobile native and hybrid application file, that is the apk, ipa, and app file, is not uploaded on Perfecto automatically during the Qualitia Automation Studio executions.
Qualitia recommends that you perform the following steps to upload the native and hybrid mobile application file:You must upload mobile native or hybrid applications on Perfecto Cloud before executing test suites.
To upload a mobile app, login to Perfecto website, click Assets and Setup > Upload.After the mobile app is uploaded, copy the Perfecto lab repository path for your mobile app.
Enter the Perfecto lab repository path in the first parameter of Mobile.OpenApp action.
Qualitia Automation Studio 8.1.0 Release Notes
New Features
Parallel Execution of Test Cases for a Azure DevOps Pipeline
You can now execute multiple test cases for a Azure DevOps pipeline in parallel. All you need to do is configure multiple Azure DevOps agents with the Qualitia Remote Agent.
Azure DevOps Pipeline Executions in Real Time Reporting
The Real Time Reporting portal now shows the test case executions in real-time for a Azure DevOps pipeline.
Introduction of CompareSubString Action
The CompareSubString action verifies whether a string or any of its substring is defined in the desired pattern that you want. For more information, refer to General Web Actions .
Enhancements
When a task is removed from the Test Case Editor screen, the selection focus now moves to the previous logical unit (Test Case step, Task, If Block) instead of the first line of the test case.
Enhancements have been done to improve the error logging.
QAS now supports MOS and Mobile Recorder for iOS platform version 14.x.
MOS and Mobile Recorder now support web view on simulator and real device for iOS web and hybrid applications.
The offline package logging is updated to match the QFD version logging for enabling dependency on specific log formats.
Updated the PrintMessageInReport action to support backward compatibility for the Qualitia for Desktop v4.3.x projects migrated to QAS 8.x.
Bug Fixes
Fixed the issues where the applications stopped responding during successive project changes.
Fixed the authentication issue that were seen while logging into the Reports and Dashboard portal.
Fixed the issue where an incorrect object class was mapped to a custom action.
Fixed the issue where the suite execution reports for Azure DevOps pipeline executions did not display the execution start and end time.
Fixed the issues related to migration of the desktop projects from Qualitia for Desktop v4.3.x to QAS 8.x.
Fixed the Date-Time formatting issue in the Sync TSR feature and the Sync TSR button visibility.
Fixed the issue related to incorrect migration of the ComputeExpression action for the desktop projects migrated from Qualitia for Desktop v4.3.x to QAS 8.x.
Fixed the issues in the reporting of parallel execution of a test suite using Power Shell utility. The Qualitia Parallel Execution Report is now generated if you abort the execution by pressing Ctrl+C from the PowerShell console.
Known Issues
While upgrading from a previous QAS version, the saved browser binary does not work correctly. This causes the browser to close immediately when you are recording a session.
To work around this issue, update the browser binary to replace the existing browser binary even if it is the same at the following location:
%localappdata%QualitiaWDClient/SeleniumThe Excel.WritetoColumn and Excel.WritetoRow general actions are not working correctly.
During a MOS or Mobile Recorder Session, if you switch from a native-context to the web-context view, the web-view may get distorted for an iOS hybrid application on a real device having iOS version 12.4.5.
While recording a hybrid application, by default, the Page Refresh option is set to Auto mode by in the web view context.
The SelectWindowUsingURL action may sometimes fail to execute on Internet Explorer.
During execution, if you switch from the native-context to the web-context of the hybrid application, the screenshots for the steps executed on the web-context are not displayed in the Execution Summary Report.
To work around this issue:Open the associated execution profile.
Click Edit Desired Capabilities > Android.
Select the nativeWebScreenshot checkbox.
Set nativeWebScreenshot to True.
Click Update.
In desktop projects, if you add a test data with a double quote, it is replaced with an empty data.
Qualitia Automation Studio 8.0.5 Release Notes
Enhancements
Selecting an object in the object repository allows you to view the details of the object and also its child objects on the main page.
Updated the Writelog action for handling the pass message.
Updated the VerifyExistence action to display the appropriate message in the Info Log details.
Bug Fixes
Fixed the issues related to editing child objects. Now you can select a child object directly and edit or remove it, without having to first select the parent object.
Fixed the issues to allow you to edit or remove an object that is selected using the Find option.
Fixed the issue where after editing any object name, it is reflected in the left pane immediately. Now you are no longer required to switch to other tabs and return to the Objects tab to see the updated object name.
Fixed the issue where the new properties added to an object were not displayed.
Fixed the issue with Qualitia executable process, which would remain active in the background even after closing the QAS client.
Fixed the issues in the Wait actions to enable working in the Explicit wait mode.
Fixed the issues related to saving test cases when objects are identified using the Google Chrome Object Spy.
Known Issues in Qualitia Automation Web Recorder
Recording the Enter key as a SendKeySequence Action as is not supported.
To work around this issue, add a blank step manually in the test case, select the SendKeySequence Action, and type Enter as its parameter value.Recording the SendKeySequence Actions using Internet Explorer is not supported. To work around the issue, Press the Tab button of your keyboard, and then record the SendKeySequence Action that you want.
Known Issue in MOS or Mobile Automation Recorder
Sometimes switching from one tab to another tab in the web-view context for a mobile application on an iOS simulator may fail. To work around this issue, switch to the native-context, activate the tab of the mobile application that you want to open, and then switch to the web-view context to select the tab that you want.
Qualitia Automation Studio 8.0.4 Release Notes
New Features
Introduced the Keep Dry Run Reports option, which does not overwrites the reports of the previous dry runs. For more details, refer to /wiki/spaces/T2/pages/2681539730.
Bug Fixes and Enhancements
Enhancements
The QAS server upgrade process now handles the Unit Test stubs for the projects integrated with TFS/Azure DevOps. You are no longer required to re-publish the test cases after upgrading the TFS/Azure DevOps integrated projects.
Significant performance improvements have been made in the following areas:
Test case management
Object management
Project management
Local data cache management
SaveAs Project feature
The location of TFS/Azure DevOps Remote Agent working folder has been moved to the localappdata folder to avoid conflicts.
Cosmetic user interface changes done to improve the user experience.
Enhancements in the object identification for web elements using Smart locator with text strategy in the following scenarios:
Creating objects manually in QAS
Adding objects using the the Qualitia Automation Web Recorder
Learning objects using Chrome object spy and IE object spy
Enhancements in the SmartLocator algorithm.
Bug Fixes
Qualitia Automation Studio now allows you to save test cases with empty test data (cells containing only spaces).
Fixed the issue related to the data type while passing variables to the Vbscript engine for the test case executions on the Desktop applications.
Fixed the issue with test case exit flags in a test suite. When you save a test suite, the existing test case exit flags do not reset to Continue (Green flag) anymore.
Fixed the issues related to the test data of the projects that are migrated from QFD. Now the correct test data is shown for those actions whose parameter sequence has changed.
Minor fixes related to object identification are done.
Known Issues
The following error message appears when you open a test case of a project that is migrated from QAS v7.x:
Object Reference not set to the instance of the Object.
To work around this issue, after you complete the project migration, delete the DBCache folder, which is located at the following location:
%localappdata%\Qualitia\WD\Client\Settings\<Project Folder>\DBcacheThe QAS client crashes if it remains idle for more than 12 hours on a virtual machine.
Qualitia Automation Studio 8.0.3 Release Notes
Dropped Feature
Qualitia has dropped MOS and Qualitia Automation Mobile Recorder support for iOS version 10.4 and earlier.
Bug Fixes and Enhancements
Removed check-in of DBCache and environment variables in Git to avoid conflicts when using Git as the version control system.
Improved the Object Selection performance in the Test Case Editor screen.
Fixed the synchronization issues between Qualitia Design Studio and Qualitia Automation Studio.
Fixed the issue related to publishing custom actions during Azure DevOps integration.
Fixed the issue where custom action execution in Azure DevOps integration was skipped intermittently.
Known Issues
Known Issues in Settings
QAS client does not prompt any error message if the Java path is blank in the General Settings screen.
Known Issues in MOS and Qualitia Automation Mobile Recorder
MOS and Qualitia Automation Mobile Recorder do not support iOS versions 14.x and later.
Hovering over a web element may fail to highlight the web element if the page contains multiple iframes. In this case, MOS/MR displays the "Failed to execute method" error message.
To work around this issue, Qualitia recommends to record the web element using the Qualitia Automation Web Recorder for the specific step.
Known Issues in QDS Integrated Project
If you create a task using steps of a test case in QAS, then QDS does not display the updated test case and the created task.
Changing the order of tasks in QDS for the test case which has a Test Data in QAS corrupts the test data in QAS. Also, you cannot edit or save the test case in QDS.
To work around the issue, perform the following steps:Export the test data of the affected test case. This allows you to use the test data partially again.
Detach all the tasks and remove all the TC steps from the Test Case in QAS.
Import the same tasks in the required order and add the TC steps again at the appropriate places. However, you need to add the test data again using the data from the exported excel sheet appropriately.
New Feature
Introduction of Rest.Patch.Execute.API action.
This PATCH API action updates the partial resources, which can be used as an alternative to the PUT API action. Typically, PATCH API actions are light-weight and consume less bandwidth when compared to the PUT API actions. For more information, refer to Rest.Patch.ExecuteAPI.
Dropped Feature
Mobile Object Spy and Qualitia Automation Mobile Recorder has dropped supporting iOS versions 10.4 and earlier.
Enhancements
Multiple enhancements are done to the user interface to improve usability.
Improved the error message that is displayed when you create a project that already exists in the target database server.
Improved the error message to highlight the set of characters allowed in a project name while creating a project.
Enhanced the info logs for wait actions. Info logs now display the actual values used in wait action executions.
Added support to integrate Azure DevOps Git repository as a version control tool in addition to Bitbucket and GitHub.
When a user edits a task, other users can now view the following information:
The user who edited the task
The date and time when the task was edited
Earlier, only the following message was displayed:
"Some tasks in the test case have been modified".
Added support for specifying a relative path to the AttachFile action.
Added support to update the expired password in the ALM integration settings.
Added support to update the expired password in the Azure DevOps integration settings.
Added support to install Qualitia Automation Studio for multiple user profiles on a Virtual Machine even when other users are actively using Qualitia Automation Studio.
Fixed Issues
Fixed an issue related to the latest setup files for Qualitia Web server setup not getting updated to the latest version during the Server upgrade process.
Fixed the issue where the IF conditional statements that were migrated from QFD did not work.
Known Issues
Actions
The WindowsAuthenticationLogin action does not work on Safari.
The PressKeys action does not execute on the inactive screen of the VM for the following keys and key combinations.
NUMLOCK
CAPSLOCK
SCROLLLOCK
PRTSC
Ctrl+Shift+Tab
Ctrl+N
Alt+F4
Ctrl+Shift+T
Ctrl+W
Ctrl+F4
Ctrl+F5
Alt+Home
Ctrl+
Ctrl-
Ctrl+Shift+Del
Ctrl+J
Ctrl+P
Ctrl+O
Ctrl+U
Defect Management Systems
The defect management system integration settings are not preserved during migration to 8.0.x. After completing the migration, you must manually re-configure the defect management system integration settings.
You cannot directly change the settings in the Defect tab of Project Settings if you want to replace the mapping of a Qualitia Project to another Jira/TFS project.
To replace the mapping for a Qualitia project with another Jira/TFS project, perform the following steps:Do one of the following:
Go to Admin > Project, under the Configuration column, click Configure next to a project.
Go to Settings > Project Settings.
Click the Defects tab.
Select the Target Defect Management System to None.
Click Ok.
You can now integrate the Qualitia project with another Jira/TFS project. For more information, refer to Defect Management Systems .
Mobile Object Spy and Qualitia Mobile Recorder
When capturing an object on an SMS application, the object name is appended with null.
Unable to start a session after selecting an application in MOS or Mobile recorder on Xcode version 11.6 or higher. To work around this issue, refer to Unable to Start a Session on Xcode.
MOS and Qualitia Automation Mobile Recorder do not support iOS versions 14.x and later.
Mobile Object Spy
Clicking any object field displays the following message unnecessarily:
”Object updated successfully”For an empty object, if you click its object class, the locator type is automatically selected as ID.
To work around this issue, from the Locator Type drop-down list, select the desired locator type you want.The empty object scenario does not work correctly on iOS.
No error message is displayed when you click the locator field values for an empty object. However, you can edit the empty object normally by selecting the class, type, and value.
Qualitia Automation Studio 8.0.1 Release Notes
Enhancements
Qualitia now supports the Windows Authentication Login Action in Firefox browser and Selenium Grid Executions (Chrome and Firefox)
Bug Fixes
Fixed the minor issues in UI, suite executions, and configuration settings.
Fixed an issue related to Offline Suite executions.
An offline suite execution fails if it contained an encrypted password that is defined in the associated Environment Variables.
Known Issues
The Web Dashboards display the execution results as per the time zone of the QAS server. However, the Realtime Reporting portal displays the execution results as per the local time zone of your computer.
Hence, for the suite executions that occur in a time zone different than QAS server’s time zone, the date and time for the execution results displayed on Real Time Reporting Portal and Web Dashboard might be different.
Qualitia Automation Studio 8.0.0 Release Notes
In this release, we have gone the extra mile to enhance your test automation experience. This new and improved version will help you to build robust tests like never before.
New Execution Engine
UI for Offline Package: Update Qualitia settings and capabilities which are needed for offline executions. There is no need for a manual update of properties or JSON files.
Execution Profiles: Create different profiles for a suite that you can execute against them. For example, profiles for cloud execution, local execution, and remote execution.
For more information, refer to /wiki/spaces/T2/pages/2681539904.Stop Execution: Stop execution in between a Dry run or Suite run from QAS itself.
Support of object data type in StoreHashMap: Store and read any Java object in StoreHashMap in custom actions.
Failure Classifications: Now provide failure reasoning along with step message in custom actions.
Failure classification gives more actionable insights to users to work on.
Qualitia Automation Studio Recorder
Now record operations performed on the application under test and convert them into ready-to-execute automation test cases. Qualitia recorder automates and simplifies the process of creating test cases. This feature allows you to
Create test cases for Web/Mobile applications, or a combination of both.
Capture the actions performed on the application as steps and store them as objects, along with the associated actions and parameters.
Pause recording whenever needed. Start/Resume recording from any step in the test case editor. Use the Test Case Editor to group the steps under separate tasks
For more information, refer to /wiki/spaces/T2/pages/2681539315 .
Real Time Reporting
Now get suite execution results at real time. The Real Time Reporting Tool allows you to monitor the test suite executions that are in progress. It updates the results of a test suite execution in real-time as each test case iteration is executed. Using this feature, you can:
Access logs & screenshots for test case executions
Monitor all Suite executions in real time, including offline executions
Access execution reports of all the suite executions run by all users in a project
View offline reports at the end of each test case iteration
Access reports for even aborted executions up to the point of failure
Improved compatibility to view results with popular browsers
For more information, refer to Real Time Reporting Portal .
Single Offering for Desktop, Web and Mobile
Now use the same Qualitia version for testing Desktop and Web/Mobile applications.
Additional features of Web projects will now be available for desktop projects as well·
Support for empty objects in desktop type of projects
Debugger support for desktop projects
Error navigation in test case and tasks for empty/deleted objects
Additional Features
Apply settings for custom actions and version control at a project level. This means that you can create different settings for different projects.
Create multiple execution profiles and select a particular execution profile during suite execution. An execution profile is a pre-defined set of configuration settings, which can be used to execute test suites. You can add multiple execution profiles with the different combinations of configuration settings. Use the new user interface for editing profile settings and desired capabilities.
Maintain multiple execution profiles for an offline package and edit the profiles using a simple user interface.
Developing Custom Actions has become more object-oriented as you can access Qualitia Public APIs.
Known Issues
The following are the known issues in Qualitia Automation Studio 8.0.0.
Qualitia Automation Studio
In Project Save As Feature, the custom action files from the source project are not moved automatically to the target project. After the project is saved, you need to manually move the dependent jars and Custom Action Function codes associated with the custom actions (keywords) that were selected during Save As process.
When editing a test case, if you make any changes and go to the search box to search a test case without saving the changes, you are prompted to save the changes. If you click Yes, the Scenario tree shows the test case with matching criteria, but the changes are not saved. You must save the changes that you made to a test case before you perform a search on the Scenario tree.
In a desktop project, if you search for an object that is a part of a long hierarchy in the Objects tree, clicking Next does not scroll up to the highlighted object.
The Desktop web executions are not tested on Macintosh computers.
Execution of test case steps on Web and Hybrid Apps using Android emulator takes longer time.
To work around this issue, do one of the following:
Open the mapped execution profile and disable all the options of Screen Capture On .
Open the mapped execution profile, click Mobile > Edit Desired Capabilities, and set nativeWebScreenshot to true.
The Click action may fail to execute if the Mobile checkbox object is added using the ID locator type. To work around this issue, use XPath locator type for adding the Mobile checkbox objects.
The Mobile.SelectWebViewUsingURL action may fail on some versions of iOS. During testing, the action failed on Simulator iPhone 8 with PlatformVersion 13.3.
Qualitia does not support nested environment variables. The test cases that were created using previous QFD versions, having nested environment variables will fail upon execution.
Qualitia supports only basic data types such as Number and List/Option, for integration with Defect Management Systems (Jira and TFS). Qualitia does not support complex data types such as custom user-defined data types, nested objects, and dates.
If you switch to another project from Qualitia client, the current MOS session does not change. To work around this issue, log out from MOS, log in again, and select the correct project.
TFS/Azure DevOps Integration
The Qualitia Remote Agent resets the execution settings when you upgrade to Qualitia 8.0. In this situation, you must configure the execution settings again.
Qualitia Automation Recorder
Common Issues
If the XPath locator value for an object contains a Unicode value, it is taken as a blank space while dry run and suite execution. As a result, the execution fails as Qualitia does not identify the object.
To work around this issue, edit the object using a locator type other than XPath.
While a recording session is active, if you dry run the test case and then stop it manually, the recording session also stops.
Qualitia Web Recorder
If you start a recording session and close the browser immediately, the recording session does not stop automatically. Also, you need to close the recorder launching progress bar using Windows Task Manager.
Before recording the verify and wait actions for a table, you must select the table.
Qualitia Web Recorder does not support Shadow DOM.
If you use Internet Explorer for recording, you can record the objects of the Security Certificate dialog box. However, when you dry run the test case, the recorded steps associated with the Security Certificate dialog box fail.
Specific to SFDC Application
You cannot record the actions on the objects of permission request popups. To work around this issue, you need to manually add the steps with actions such as AcceptDialog and DismissDialog.
If you select an item from a list, the recorder does not record the SelectItemByText action, but it records a step with the Click action and the selected list item as the object.
Qualitia Mobile Recorder
You cannot record the objects when launching the application in the Android device, the auto-fill popup appears. The workaround is to disable the auto-fill popup.
You can disable the appearance of auto-fill popup in the Android 10 device as follows:Settings >> Language and Input >> Autofill service >> Click and select option as None
For other Android versions, you need to check with the relevant Android Version documentation.
Qualitia Mobile Recorder does not support recording web and hybrid applications on an Android emulator that is connected to a Macintosh agent.
Simulators and real devices having iOS version 13.3 do not support native applications.
The following iOS platforms do not support recording and Mobile Object Spy for the web applications and web-view context of hybrid applications:
All the iOS simulators versions
Real devices having iOS version 12.2 or above
For the projects upgraded from the previous Qualitia versions, if you record a test case, then for every object, multiple pages and objects are created in the object repository.
To work around this issue, after upgrading the project, change the locator type and value of the Page object to XPath and “//app”.
Unable to connect to a device intermittently. To work around this issue, restart the recording session.
While recording a web application, if you update the URL in the address bar, it is not recorded as a step. You need to enter a step manually with action as OpenURL and add the new URL in the parameter.
Reports and Dashboard Portal
If you have not specified an operating system version in the associated execution profile for suite executions on SauceLabs and BrowserStack, the Real Time Reporting Portal does not display the operating system version for these suite executions.
If you change the defect management system for a Qualitia project, then the suite execution summary reports that are already open in the browsers show the old defect management system details to log a defect manually.
In such situations, you can log in to the Real Time Portal or access the Test Suite Execution Summary report from the Suite of Suites screen to log a defect manually using the new Defect Management System.For the desktop applications suite executions, the execution time for the first test case iteration does not include the UFT launch time. Hence, for these suite executions, the execution start time shown in the Real Time Reporting Portal and Web Dashboard differ.
If you are using Firefox to access the Real Time Reporting portal, the white borders in the table grids for the reports are not displayed. This is caused due to a known issue in Firefox.
For a test case step, you can edit the text under Name/Condition column in the test case editor screen and save the test case. However, after executing the associated test suite, the Suite Execution report screen displays the original test under the Hierarchy column
The design of Real time Reporting Portal is not mobile responsive. Therefore, you can expect some UI distortions when viewing the portal through the mobile device having a resolution lower than 1100px.
Custom Actions for Desktop Projects
You cannot add or remove parameters from a custom action for a mapped function on Custom Action window. To work around this issue, launch the associated VBS file from Qualitia client, add or remove parameters for the mapped function, and remap the function to the custom action from Custom Action window.