Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 26 Next »

The Object Repository Manager of MicroFocus Unified Functional Testing (UFT) adds and maintains the set of objects as tsr files. For more information on this, please refer to the UFT One Help Center.

The purpose of having OR objects is to store all the objects present in the tsr file automatically. All you need is to ensure syncing the OR objects whenever the tsr file is updated. You cannot add, modify or remove OR objects manually.

On this page:

Mapping a tsr file with a Qualitia Project

Once you create a tsr file containing the objects of an application under test, you can map it with a desktop project. 

If you have defined the location of the associated tsr file in the Global TSR Path while creating the project, then you can view the OR objects in the objects screen of the project.

To map a tsr file with a Qualitia project:

  1. Go to Admin > Projects.

  2. Click Edit to next of the desktop project for which you want to map with a tsr file.

  3. Enter the location of the tsr file, in Global TSR Path.

  4. Click Save.
    The Objects screen displays all the objects in the OR tree node of the Objects screen.

Syncing OR Objects with a tsr File

After specifying the tsr file path in Global TSR path field of Project settings, you need to sync the OR objects every time the associated tsr file is updated.

Before syncing process starts, you can preview to check whether all the objects in the updated tsr files are present to create the required test cases.

  • On the Objects screen, you can view the complete information for all the objects including the last date and time on which it was updated and synchronized from tsr.

  • If you have started syncing the OR objects, then other users cannot sync or cancel the syncing process, until the synchronization completes.

  • If the object name contains a Non-English character, the report might not display it correctly.

  • If the tsr file contains objects that Qualitia does not supports, then report displays such objects in the report.

To sync OR objects with a tsr file:

  1. Open the Qualitia project for which you need to update its OR objects.

  2. Click the Develop tab.
    Note: If your test cases are ready, then you can sync from the Execute tab.

  3. Click the Sync TSR button placed at the top-right corner.

  4. Do one of the following:

Click

To

Preview

Preview the new set of objects as a report in a CSV format. The reports shows all the objects that are new, modified, and deleted by comparing with the current OR objects.

After viewing the objects in the report , you can click Proceed or Abort as explained in this table.

Proceed

Sync with the updated objects of the tsr file.

Abort

Cancel in syncing with the updated objects of the tsr file.

After the syncing process completes, in the OR node, all the deleted objects are highlighted in red along with an exclamatory mark.

You can replace the deleted objects in the associated test cases with another objects. To know the associated test cases for the deleted objects , refer to Working with View Test Cases Feature .

Replacing the Mapped tsr File

Perform the following steps to replace the mapped tsr file with another tsr file.

To replace a mapped tsr file for a project:

  1. Go to Admin > Project.

  2. Click Edit to next of the project for which you want to replace its mapped tsr file.

  3. Click Browse to locate another tsr file, in Global TSR Path.

  4. Do one of the following:

Click

To

Preview

Preview the new set of objects as a report in the CSV format. The reports shows all the objects that are new, modified, and deleted by comparing with the current OR objects.

After viewing the objects in the report , you can click Proceed or Abort as explained in this table.

Proceed

Map the OR objects with the new tsr file.

Abort

Cancel in mapping the OR objects with the new tsr file.

After the tsr file is replaced, in the OR node, all the deleted objects are highlighted in red along with an exclamatory mark.

You can replace the deleted objects in the associated test cases with another objects. To know the associated test cases for the deleted objects , refer to Working with View Test Cases Feature .

  • No labels