Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

In order to trigger test case execution from the HPE ALM agent, Qualitia must connect to HPE ALM.

To connect Qualitia to HPE ALM database:

  1. Log on to Qualitia Automation Studio.
  2. On the Settings menu, go to Configuration Settings > HPE ALM.
  3. Select the Integrate with HPE ALM option.
  4. On the Execute screen, click Export.
    A dialog box opens.
  5. Enter information as mentioned in the table below.


Field

Description
ALM Server URLEnter the ALM Server URL. This URL contains host and server details where HPE ALM exists.

For Example: 192.168.22.34:8080/qcbin
ALM UsernameEnter username to access HPE ALM.
ALM PasswordEnter the password to access HPE ALM.  
ALM Project.Enter the HPE ALM project name (case-sensitive) to which you want to add Qualitia test cases.
(warning) One Qualitia project can be linked to one HPE ALM project only.
ALM DomainEnter the HPE ALM domain (case-sensitive) to which you want to add Qualitia test cases.

4. Click Test Connection to ensure that Qualitia is connected to the respective HPE ALM project.