Table of Contents |
---|
...
Qualitia Configuration File does not exist, can you please save Qualitia Configuration.
This issue occurs when the configuration file is missing. The file is created when you save the configuration settings for the first time.
Solution:
- Log on to Qualitia Automation Studio.
- On the Settings menu, click Configuration Settings.
- Click Save.
...
When trying to log in into Qualitia, the user may get the following error [when the machine is cloned with Qualitia Installation].
Qualitia License Key Not Found. (H0007)
Solution:
...
Open the UFT, specify the application URL, and the browser as Internet Explorer.
Click the Record button.
A pop-up message opens which shows the message as “Some third-party add-ins are required to launch this URL. Do you want to enable these add-ins?”Click Yes to enable the required add-ins.
Record few steps and save them.
Run them through UFT.
If the execution is successful, open the Internet Explorer, and check the name of new add-in enabled.
Run the test case through Qualitia.
Unable to Launch Qualitia Desktop Client
Problem: The Qualitia Client is not opening and also you do not see any error message.
Reason: Your organization’s security policies may be restricting the Qualitia Client from opening.
Workaround: Perform the following steps to resolve the issue.
Go to %Localappdata%\QualitiaQTPClient\app-x.x.x.
Note:x.x.x refers to the Qualitia for Desktop version you have installed.Open the Qualitia.exe.Config file.
In the <runtime> node, between </assemblyBinding> and </runtime>, enter the following tag:
<enforceFIPSPolicy enabled="false" />Save the configuration file.
Open the Qualitia Client.