Table of Contents | ||
---|---|---|
|
Installation and Upgrade Process Issues
...
- Navigate to %localappdata%\QualitiaWDServer\app-5.2.0\Server.
- Open the application.properties file.
- Update value for server.port.
- Save and close the file.
- Restart the Qualitia Server service from the Services console and continue installation.
Exception in UpgradeProjectDatabase : <Project_Name>: Too many connections.
This error occurs when the number of projects is more than 50. In order to proceed with the upgrade process, you must then increase the limit of maximum connections allowed in the MySQL database settings. By default, 151 is the maximum permitted number of simultaneous client connections.
...
To resolve this error, you must install Microsoft Visual C++ 2010 SP1 Redistributable package.
Root Cause: java.lang.Exception: C:\Users\<Username>\AppData\Local\QualitiaWDClient/WebDriver\Config/android.properties file does not exist.
Solution:
This error occurs when Qualitia is launched using the incorrect shortcut and user tries to execute the test case for Mobile web or native application.
...
Teamcity Agent Running Headless Execution on Window Server System
Qualitia seamlessly integrates with TeamCity, Bamboo, Jenkins continuous integration tools. Sometimes users are unable to view the test case execution on the designated TeamCity build agent.
It is observed that setting the right Java path resolves this problem. You can try below:
...
Qualitia Configuration File does not exist, can you please save Qualitia Configuration.
This issue occurs when the configuration file is missing. The file is created when you save the configuration settings for the first time.
This issue may occur when creating offline package (from File > Offline Package) as well.
Solution:
- Log on to Qualitia Automation Studio.
- On the Setting menu, click Configuration Setting.
- Click OK.
- Now create an offline package from File > Offline Package.
...
Resetting Password for System Users.
For system users, Qualitia uses the password of the machine where Qualitia client is installed. This password would only be changed if the user updates machine / AD / LDAP password.
Qualitia License Key Not Found. (H0007)
Solution:
...
Task Iteration Executions
Task Iterations Not Getting Executed
Problem: Some task iterations are
...
skipped.
Summary: In task iterations,
...
some iterations execute, but the remaining task iterations do not execute or none of them are executed.
Solution:
You need to delete the blank cells associated with task iterations.
Perform the following steps:
Open the test case in which task iterations
...
did not execute.
Open its Test Data explorer.
Select the blank cells of the following columns, and Press Delete from your keyboard.
TCIteration
Selection
DataSetTag
Note: All the cells can be deleted in a single go except for the first cell immediate below to DataSetTag. You need to delete this cell separately.