...
Note: Ensure a backup of the workspace folder from Qualitia Automation Studio - Server is taken before the upgrade; otherwise, rollback may result in data loss.
Steps for Rollback:
Uninstall Qualitia Server:
Go to Control Panel > Programs and Features, select Qualitia - Server, and uninstall.
Uninstall Qualitia Client:
In Control Panel > Programs and Features, select Qualitia - Client and uninstall.
Delete Server Folder:
Navigate to
C:\ProgramData\Qualitia Automation Studio – Server
and delete the Qualitia - Server folder.
Delete Client Folder:
Go to
%localappdata%
and delete the Qualitia Automation Studio – Client folder.
Install Previous Qualitia Server Version:
Install the previous version of Qualitia - Server from your saved setup files.
Stop the Qualitia Web Service:
Open Services (
services.msc
), find qualitia-web-service, and stop it.
Delete Current Workspace Folder:
In
C:\ProgramData\Qualitia Automation Studio – Server
, delete the workspace folder.
Restore Backup of Workspace Folder:
Copy the previously backed-up workspace folder into
C:\ProgramData\Qualitia Automation Studio – Server
.
Restart the Qualitia Web Service:
Go back to Services, find qualitia-web-service, and start it.
Download and Install Qualitia - Client:
Go to the Qualitia portal, download the Qualitia - Client, and install it.
Launch Qualitia - Client:
Open the Qualitia - Client, navigate to the Develop tab, and allow the project to download.
...