  • You cannot record the objects when launching the application in the Android device, the auto-fill popup appears. The workaround is to disable the auto-fill popup.
    You can disable the appearance of auto-fill popup in the Android 10 device as follows:

    Settings >> Language and Input >> Autofill service >> Click and select option as None     

    For other Android versions, you need to check with the relevant Android Version documentation. 

  • Qualitia Mobile Recorder does not support recording web and hybrid applications on an Android emulator that is connected to a Macintosh agent.

  • Simulators and real devices having iOS version 13.3 do not support native applications.

  • The following iOS platforms do not support recording and Mobile Object Spy for the web applications and web-view context of hybrid applications:

    • All the iOS simulators versions

    • Real devices having iOS version 12.2 or above

  • For the projects upgraded from the previous Qualitia versions, if you record a test case, then for every object, multiple pages and objects are created in the object repository.

    To work around this issue, after upgrading the project, change the locator type and value of the Page object to XPath and “//app”.

  • Unable to connect to a device intermittently. To work around this issue, restart the recording session.

  • While recording a web application, if you update the URL in the address bar, it is not recorded as a step. You need to enter a step manually with action as OpenURL and add the new URL in the parameter.

Reports and Dashboard Portal

  • If you have not specified an operating system version in the associated execution profile for suite executions on SauceLabs and BrowserStack, the Real Time Reporting Portal does not display the operating system version for these suite executions.

  • If you change the defect management system for a Qualitia project, then the suite execution summary reports that are already open in the browsers show the old defect management system details to log a defect manually.
    In such situations, you can log in to the Real Time Portal or access the Test Suite Execution Summary report from the Suite of Suites screen to log a defect manually using the new Defect Management System.

  • For the desktop applications suite executions, the execution time for the first test case iteration does not include the UFT launch time. Hence, for these suite executions, the execution start time shown in the Real Time Reporting Portal and Web Dashboard differ.

  • If you are using Firefox to access the Real Time Reporting portal, the white borders in the table grids for the reports are not displayed. This is caused due to a known issue in Firefox.

  • For a test case step, you can edit the text under Name/Condition column in the test case editor screen and save the test case. However, after executing the associated test suite, the Suite Execution report screen displays the original test under the Hierarchy column

  • The design of Real time Reporting Portal is not mobile responsive. Therefore, you can expect some UI distortions when viewing the portal through the mobile device having a resolution lower than 1100px.

Custom Actions for Desktop Projects

You cannot add or remove parameters from a custom action for a mapped function on Custom Action window. To work around this issue, launch the associated VBS file from Qualitia client, add or remove parameters for the mapped function, and remap the function to the custom action from Custom Action window.