Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Table of Contents
maxLevel2

...

  1. Navigate to %localappdata%\QualitiaWDServer\app-5.2.0\Server.
  2. Open the application.properties file.
  3. Update value for server.port.
  4. Save and close the file.
  5. Restart the Qualitia Server service from the Services console and continue installation. 

Exception in UpgradeProjectDatabase : <Project_Name>: Too many connections.

This error occurs when the number of projects is more than 50. In order to proceed with the upgrade process, you must then increase the limit of maximum connections allowed in the MySQL database settings. By default, 151 is the maximum permitted number of simultaneous client connections.  

...

To resolve this error, you must install Microsoft Visual C++ 2010 SP1 Redistributable package.


Image Modified

Root Cause: java.lang.Exception: C:\Users\<Username>\AppData\Local\QualitiaWDClient/WebDriver\Config/android.properties file does not exist.

Solution:

This error occurs when Qualitia is launched using the incorrect shortcut and user tries to execute the test case for Mobile web or native application.

...

Teamcity Agent Running Headless Execution on Window Server System

Qualitia seamlessly integrates with TeamCity, Bamboo, Jenkins continuous integration tools. Sometimes users are unable to view the test case execution on the designated TeamCity build agent. 

It is observed that setting the right Java path resolves this problem. You can try below:

...

Qualitia Configuration File does not exist, can you please save Qualitia Configuration.

Image Modified

This issue occurs when the configuration file is missing. The file is created when you save the configuration settings for the first time.

This issue may occur when creating offline package (from File > Offline Package) as well.

Solution:

  1. Log on to Qualitia Automation Studio.
  2. On the Setting menu, click Configuration Setting.
  3. Click OK.
  4. Now create an offline package from File > Offline Package.

...

Resetting Password for System Users.

For system users, Qualitia uses the password of the machine where Qualitia client is installed. This password would only be changed if the user updates machine / AD / LDAP password.

Qualitia License Key Not Found. (H0007)

Image Modified

Solution:

In case you come across this error:

...

Multiexcerpt include macro
nameAttachFile-Note
pageQFWM:General Web Actions

Importing Offline Package Report

Description: Upon importing an offline package report, Qualitia sometimes might prompt an error message

that “Projectname_projectdb.tblsuite_summery does not exist”.

Solution: You need to navigate to any other tab such as Development or Execution and return to the Reports tab. If the problem persists, restart the Qualitia client.

Failed to Connect JIRA. Verify Username/Password

...