Table of Contents | ||
---|---|---|
|
...
- Navigate to %localappdata%\QualitiaWDServer\app-5.2.0\Server.
- Open the application.properties file.
- Update value for server.port.
- Save and close the file.
- Restart the Qualitia Server service from the Services console and continue installation.
Exception in UpgradeProjectDatabase : <Project_Name>: Too many connections.
This error occurs when the number of projects is more than 50. In order to proceed with the upgrade process, you must then increase the limit of maximum connections allowed in the MySQL database settings. By default, 151 is the maximum permitted number of simultaneous client connections.
...
Filename too long (Git-version control system)
The older version of GIT has a restriction about file path. It does not accept the files that exceed the file path and name that has more than 256 or 260 characters.
...
- Workaround 1: Update the Git version to the latest one.
Workaround 2: Change Git settings by executing this command:
Code Block git config --system core.longpaths true
Workaround 3:
Update the registry key (in Windows 10, version 1607, and later)
HKLM\\SYSTEM\\CurrentControlSet\\Control\\FileSystem LongPathsEnabled (Type: REG_DWORD) should be set to 1.Info If any of the workaround mentioned above does not work or you are unable to follow these workarounds due to any permission-related issues, you can move the Qualitia project to some local drive. Moving the project to the local drive saves some character space and may resolve the issue.
Expand title view image
Exception Occurred While Launching Chrome. X Attempts Exhausted.
...
To resolve this error, you must install Microsoft Visual C++ 2010 SP1 Redistributable package.
Root Cause: java.lang.Exception: C:\Users\<Username>\AppData\Local\QualitiaWDClient/WebDriver\Config/android.properties file does not exist.
Solution:
This error occurs when Qualitia is launched using the incorrect shortcut and user tries to execute the test case for Mobile web or native application.
...
Teamcity Agent Running Headless Execution on Window Server System
Qualitia seamlessly integrates with TeamCity, Bamboo, Jenkins continuous integration tools. Sometimes users are unable to view the test case execution on the designated TeamCity build agent.
It is observed that setting the right Java path resolves this problem. You can try below:
...
Qualitia Configuration File does not exist, can you please save Qualitia Configuration.
This issue occurs when the configuration file is missing. The file is created when you save the configuration settings for the first time.
This issue may occur when creating offline package (from File > Offline Package) as well.
Solution:
- Log on to Qualitia Automation Studio.
- On the Setting menu, click Configuration Setting.
- Click OK.
- Now create an offline package from File > Offline Package.
...
Resetting Password for System Users.
For system users, Qualitia uses the password of the machine where Qualitia client is installed. This password would only be changed if the user updates machine / AD / LDAP password.
Qualitia License Key Not Found. (H0007)
Solution:
...