Table of Contents | ||
---|---|---|
|
...
- Navigate to %localappdata%\QualitiaWDServer\app-5.2.0\Server.
- Open the application.properties file.
- Update value for server.port.
- Save and close the file.
- Restart the Qualitia Server service from the Services console and continue installation.
Exception in UpgradeProjectDatabase : <Project_Name>: Too many connections.
This error occurs when the number of projects is more than 50. In order to proceed with the upgrade process, you must then increase the limit of maximum connections allowed in the MySQL database settings. By default, 151 is the maximum permitted number of simultaneous client connections.
...
For more information, refer to the MySQL documentation.
Other Issues
Unable to launch Qualitia Automation Studio.Could not find a part of the path 'C:\Users\<USERNAME>\AppData\Local\QualitiaWDClient\Selenium'.
This error occurs when the Selenium folder is missing in the Qualitia installation directory. This folder consists of all the browser drivers that are required for the test case executions using different browsers.
By default, this directory is created at the time of installation. The installation process may miss to create it in some specific environments.
Resolution:
To resolve this error, create a new folder in the Qualitia installation directory (%localappdata%\QualitiaWDClient), name it as selenium, and try launching Qualitia again.
Exception Occurred While Launching Chrome. X Attempts Exhausted.
...
To resolve this error, you must install Microsoft Visual C++ 2010 SP1 Redistributable package.
Root Cause: java.lang.Exception: C:\Users\<Username>\AppData\Local\QualitiaWDClient/WebDriver\Config/android.properties file does not exist.
Solution:
This error occurs when Qualitia is launched using the incorrect shortcut and user tries to execute the test case for Mobile web or native application.
...
Teamcity Agent Running Headless Execution on Window Server System
Qualitia seamlessly integrates with TeamCity, Bamboo, Jenkins continuous integration tools. Sometimes users are unable to view the test case execution on the designated TeamCity build agent.
It is observed that setting the right Java path resolves this problem. You can try below:
...
Qualitia Configuration File does not exist, can you please save Qualitia Configuration.
This issue occurs when the configuration file is missing. The file is created when you save the configuration settings for the first time.
This issue may occur when creating offline package (from File > Offline Package) as well.
Solution:
- Log on to Qualitia Automation Studio.
- On the Setting menu, click Configuration Setting.
- Click OK.
- Now create an offline package from File > Offline Package.
...
Resetting Password for System Users.
For system users, Qualitia uses the password of the machine where Qualitia client is installed. This password would only be changed if the user updates machine / AD / LDAP password.
Qualitia License Key Not Found. (H0007)
Solution:
...