  1. Navigate to %localappdata%\QualitiaWDServer\app-5.2.0\Server.
  2. Open the application.properties file.
  3. Update value for server.port.
  4. Save and close the file.
  5. Restart the Qualitia Server service from the Services console and continue installation. 

Exception in UpgradeProjectDatabase : <Project_Name>: Too many connections.

This error occurs when the number of projects is more than 50. In order to proceed with the upgrade process, you must then increase the limit of maximum connections allowed in the MySQL database settings. By default, 151 is the maximum permitted number of simultaneous client connections.  

...

To resolve this error, you must install Microsoft Visual C++ 2010 SP1 Redistributable package.


Image Modified

Root Cause: java.lang.Exception: C:\Users\<Username>\AppData\Local\QualitiaWDClient/WebDriver\Config/android.properties file does not exist.

Solution:

This error occurs when Qualitia is launched using the incorrect shortcut and user tries to execute the test case for Mobile web or native application.

...

Teamcity Agent Running Headless Execution on Window Server System

Qualitia seamlessly integrates with TeamCity, Bamboo, Jenkins continuous integration tools. Sometimes users are unable to view the test case execution on the designated TeamCity build agent. 

It is observed that setting the right Java path resolves this problem. You can try below:

...

Qualitia Configuration File does not exist, can you please save Qualitia Configuration.

Image Modified

This issue occurs when the configuration file is missing. The file is created when you save the configuration settings for the first time.

This issue may occur when creating offline package (from File > Offline Package) as well.

Solution:

  1. Log on to Qualitia Automation Studio.
  2. On the Setting menu, click Configuration Setting.
  3. Click OK.
  4. Now create an offline package from File > Offline Package.

...

Resetting Password for System Users.

For system users, Qualitia uses the password of the machine where Qualitia client is installed. This password would only be changed if the user updates machine / AD / LDAP password.

Qualitia License Key Not Found. (H0007)

Image Modified

Solution:

In case you come across this error:
  • Ensure that the license server is up and running.
  • Verify that the Sentinel LDK License Manager service is started on the Qualitia client machine. (To open Windows services console; press Windows R and then enter Services.msc) 
  • Restart the Sentinel LDK License Manager service using Windows services console.
If the issue still persists, follow the steps mentioned below:
  1. Create a file with its name in the following format - hasp_108764.ini
  2. Open this file using notepad and add the following setting in it:
    SERVERADDR = IP address of the license manager system.
    Broadcastsearch=1 
    For Example: If your license manager system’s IP address is 192.168.1.1 then setting will be: SERVERADDR = 192.168.1.1
  3. For Windows 7 and later versions, copy the hasp_108764.ini file to the following location: %localAppData%/SafeNet Sentinel/Sentinel LDK/
    Note: If not present, manually create folders SafeNet Sentinel/Sentinel LDK.
  4. Open the url http://localhost:1947 and go to Configuration > Access to Remote License Manager, select all check boxes, add required information and then click Submit.
  5. Go to Windows services console (Press Windows R and enter services.msc to open Windows Services console). 
  6. Select the service Sentinel LDK License Manager and restart it.
    You should be able to launch Qualitia with license being acquired from the remote license manager.
  7. For Verification if the license has been recognized by the license server, open the Sentinel ACC portal (http://localhost:1947) and click session to view the licenses acquired by various systems.

...