  1. Navigate to %localappdata%\QualitiaWDServer\app-5.2.0\Server.
  2. Open the application.properties file.
  3. Update value for server.port.
  4. Save and close the file.
  5. Restart the Qualitia Server service from the Services console and continue installation. 

Exception in UpgradeProjectDatabase : <Project_Name>: Too many connections.

This error occurs when the number of projects is more than 50. In order to proceed with the upgrade process, you must then increase the limit of maximum connections allowed in the MySQL database settings. By default, 151 is the maximum permitted number of simultaneous client connections.  

You can set this limit from where the   MySQL   server maintains system variables that configure its operation. System variables can be set at server startup using options on the command line or in an option filean option file.

...

Increasing Limit using

...

 Option File (Windows)

You can increase the limit using the command line interfacethis max_connections limit Using Options File (sometimes called Configurations File) 

  1. Open the command line interface and navigate to the MySQL installation directory. 
  2. Use the following command to set the new limit of simultaneous connections. 
    SET GLOBAL max_connections = <NEW_LIMIT>; 
    For example: SET GLOBAL max_connections = 252; 
  3. To check the new limit, use this command:  
    SHOW VARIABLES LIKE "max_connections" 
    You will see new limit of maximum simultaneous connectionsNavigate to C:\ProgramData\MySQL\MySQL Server 5.7 on the machine where MySQL is installed.  
  4. Edit the my.ini file using any text editor.  
  5. Update the value for max_connections 
  6. Save and Close the file. 
  7. Restart MySQL service service to get the changes affected.    

Image RemovedImage Added

For other related information, refer to the MySQL documentation. 

Increasing Limit using

...

Option

...

File

...

(

...

  1. Navigate to C:\ProgramData\MySQL\MySQL Server 5.7 on the machine where MySQL is installed.  
  2. Edit the my.ini file using any text editor.  
  3. Update the value for max_connections 
  4. Save and Close the file. 
  5. Restart MySQL service to get the changes affected.  

Image Removed

...

Linux) 

If the MySQL is installed on the Linux machine, you will find my.cnf file in the MySQL installation directory. You can update the value for max_connections in my.cnf file using any text editor.  

For more information, refer to the  MySQL   documentation. 

Other Issues

Suite Execution Fail Error: com.mysql.jdbc.Connection.isValid(I)Z

...

To resolve this error, you must install Microsoft Visual C++ 2010 SP1 Redistributable package.


Image Modified

Root Cause: java.lang.Exception: C:\Users\<Username>\AppData\Local\QualitiaWDClient/WebDriver\Config/android.properties file does not exist.

Solution:

This error occurs when Qualitia is launched using the incorrect shortcut and user tries to execute the test case for Mobile web or native application.

...

Teamcity Agent Running Headless Execution on Window Server System

Qualitia seamlessly integrates with TeamCity, Bamboo, Jenkins continuous integration tools. Sometimes users are unable to view the test case execution on the designated TeamCity build agent. 

It is observed that setting the right Java path resolves this problem. You can try below:

...

Qualitia Configuration File does not exist, can you please save Qualitia Configuration.

Image Modified

This issue occurs when the configuration file is missing. The file is created when you save the configuration settings for the first time.

This issue may occur when creating offline package (from File > Offline Package) as well.

Solution:

  1. Log on to Qualitia Automation Studio.
  2. On the Setting menu, click Configuration Setting.
  3. Click OK.
  4. Now create an offline package from File > Offline Package.

...

Resetting Password for System Users.

For system users, Qualitia uses the password of the machine where Qualitia client is installed. This password would only be changed if the user updates machine / AD / LDAP password.

Qualitia License Key Not Found. (H0007)

Image Modified

Solution:

In case you come across this error:

...